CONTACT US -  462 625 5833 -  462 625 1093

Facebook Instagram Twitter
  • Home
  • About
    • About Us
    • Certifications
  • Products
  • Services
  • FAQ
  • News
  • Careers
  • Contact
  • Home
  • About
    • About Us
    • Certifications
  • Products
  • Services
  • FAQ
  • News
  • Careers
  • Contact
Facebook Instagram Twitter

< RETURN TO ALL PRODUCTS 

COMBINED MEASURING EQUIPMENT

Combined Measuring Equipment consisting of three Integrated Measuring Transformers mounted on a metallic structure with a test board box in secondary terminals for field verification. Meets the specifications of CFE VE100-13, CFE VE100-29 and CFE 54000-56 in force. EPRECSA-CHUANGYIN trademark. Manufactured in Mexico.

Short Description     ECM-3E-13.8-8400/120-10/5 ECM-3E-13.8-8400/120-50/5 ECM-3E-13.8-8400/120-200/5 ECM-3E-23-14400/120-10/5 ECM-3E-23-14400/120-50/5 ECM-3E-23-14400/120-200/5 ECM-3E-34.5-20125/115-10/5 ECM-3E-34.5-20125/115-50/5 ECM-3E-34.5-20125/115-200/5
Voltage Nominal System Voltage (r.m.s. value) 13.8 13.8 13.8 23 23 23 34.5 34.5 34.5
Nominal Voltage and dielectric test value Maximum Design Voltage of the Equipment in kV (r.m.s. value) 15.5 15.5 15.5 27 27 27 38 38 38
Installation altitude (m.a.s.l) hasta 2500 hasta 2500 hasta 2500 hasta 2500 hasta 2500 hasta 2500 hasta 2500 hasta 2500 hasta 2500
Nominal Withstand voltage at industrial frequency Kv (r.m.s. value) Internal 38 38 38 50 50 50 70 70 70
External 38 38 38 50 50 50 70 70 70
Nominal lightning Impulse withstand voltage kV (peak value) Internal 110 110 110 150 150 150 200 200 200
External 110 110 110 150 150 150 200 200 200
Unit ratio of each secundary 70 70 70 120 120 120 175.1 175.1 175.1
Transformer Ratio (V) (Uprim:Usec) one secundary 8400:120 8400:120 8400:120 14400:120 14400:120 14400:120 20125:115 20125:115 20125:115
Transformer ratio for billing (Single-winding) 10:5 50:5 200:5 10:5 50:5 200:5 10:5 50:5 200:5
Accuray and nominal burden for measurement and protection Accuracy Class Voltage 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
Accuracy Class Current 0.2S 0.2S 0.2S 0.2S 0.2S 0.2S 0.2S 0.2S 0.2S
Protective burden range (VA) 0-50 0-50 0-50 0-50 0-50 0-50 0-100 0-100 0-100
Protective load ranges (VA) 0-15 0-15 0-15 0-15 0-15 0-15 0-15 0-15 0-15
Overcurrent Factor 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2
Power factor 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

Swipe left to see all products or download the PDF  .

Av. Río Mississipi No. 432
Col. Parque Tecnoindustrial Castro del Río
C.P. 36814, Irapuato, Gto.

Facebook Twitter Instagram

Tel. 462 625 5833 – 462 625 1093
ventas@eprecsa.mx
462 252 8893

EPRECSA © 2021. Check our  Notice of Privacy

Website developed by DigDan.

Careers

We use cookies to ensure that we give the best user experience on our website. If you continue to use this site we will assume that you agree.I agree